Mounted in own solar radiation shield (+/-0.1 deg C, 0 to 70 deg C).
No related products to display
Sorry, there are currrently no FAQs regarding the AT2-02 - Air Temperature Sensor (2m cable)
Type
Description
Measuring
range (°C)
[a]
Probe
error
Over this range
Logger
input
type
[b]
length/dia.
(mm)
Cable
details
§
ST1
General purpose thermistor probe, stainless steel sheath,
6s response
Water resistant
sheath, suitable
for burial, e.g. in measuring
soil temperature
-50 to 150
±0.2°C
0-70°C
3WR
±0.14°C
125/4.8
5m/2w
ST2
Precision thermistor probe, stainless steel sheath, 6s response
±0.1°C
SP1
General purpose Pt100 probe, stainless steel sheath, for
temperatures up to 300°C
-50 to 300
±0.6°C
4WR
±0.43°C
5m/4w
STK1
General purpose K type thermocouple probe, stainless steel sheath, for temperatures up to 250°C
-50 to 250
±1.5°C
DIF
±1.0°C
ST3
Thermistor probe with sealed sheath and leads suitable for continuous freshwater immersion
-20 to 80
BT1
Thermistor probe with sealed sheath and leads suitable for continuous sea water immersion
150/5.0
MT2
Vinyl-dipped thermistor probe, fast response, suitable for leaf temperature
2.5 diameter
MT3
Flexible miniature thermistor probe, catheter style with fast response
0 to 120
100/2.0
AT2
Precision thermistor air temperature sensor. Louvred solar radiation shield optional [c]
-30 to 70
not applicable.
3m/2w
[a] The standard range of all cables is -30 to +80°C. Higher temperature cabling can be supplied on request. [b] Additional error @ 15-25°C due to Logger.
[c] Radiation temperature error at 1kWm-2 irradiance level: 0.4°C at 3m.s1-1, 0.65°C at 2m.s-1, 1.4°C at 1m.s-1 or slower.